Svedala Demag Wheeled pavers

Differential fluid capacity & service interval

Svedala Demag wheeled pavers utilize differential fluid with a capacity range of 11,5 to 18 liters. Service intervals include checks at 50 and 250 hours, with changes required at 1000 hours or 12 months. The data covers 5 configurations.

The configuration chart below lists fill volumes and service intervals for each engine and trim variant.

TypeSpecifications
DF115P/D, Typ 34 (2007- )
  • Use: Normal
  • Capacity 18 liter
  • Check 250 hours
  • Change 1000 hours/ 12 months
DF125P/D, Typ 34 (2007- )
  • Use: Normal
  • Capacity 18 liter
  • Check 250 hours
  • Change 1000 hours/ 12 months
DF145P, Typ 656 (2007- )
  • Use: Normal
  • Capacity 18 liter
  • Check 50 hours
  • Change 1000 hours/ 12 months
DF65P, 874.... (2001- )
  • Use: Normal
  • Capacity 13 liter
  • Check 50 hours
  • Change 1000 hours/ 12 months
DF95P, 878.... (2001- )
  • Use: Normal
  • Capacity 11,5 liter
  • Check 50 hours
  • Change 1000 hours/ 12 months

Additional Notes

  • The Svedala Demag DF115P/D and DF125P/D (both Typ 34) share an identical differential fluid capacity of 18 liters, along with the same check and change intervals, indicating a common drivetrain architecture between the two models.
  • The DF145P (Typ 656) also carries an 18-liter differential capacity, placing all three Typ 34 and Typ 656 machines introduced from 2007 at the higher end of the capacity range seen across the wheeled paver lineup.
  • An 18-liter differential fill is a substantial volume, consistent with a heavy-duty axle assembly designed for the load demands of large-format paving equipment rather than a light commercial drivetrain.
  • The DF65P (serial range 874....) specifies a 13-liter differential capacity, while the DF95P (serial range 878....) specifies 11.5 liters, both introduced from 2001. The smaller capacity on the larger-numbered DF95P suggests a different axle design rather than a simple size-to-capacity relationship.
  • All five configurations share the same fluid change interval of 1000 hours or 12 months under normal use conditions, whichever comes first. The dual-trigger format means calendar time can mandate a change even when the hour threshold has not been reached.
  • The check interval differs between configurations. The DF115P/D and DF125P/D (Typ 34) specify a 250-hour check interval, while the DF145P (Typ 656), DF65P, and DF95P all specify a shorter 50-hour check interval. A 50-hour check interval reflects a more frequent monitoring requirement relative to the 250-hour interval on the Typ 34 machines.
  • All specifications listed apply to normal use conditions. No severe-duty intervals are listed for any of the five configurations, meaning the intervals shown represent standard operating environments without additional reduction for harsh or high-demand applications.

Other Systems