Reform Metrac

Power steering fluid capacity & service interval

Reform Metrac power steering fluid capacity ranges from 8 to 13 liters. Service intervals include checks at 100 and 200 hours, and changes at 35 and 600 hours or 24 months. The data covers 12 configurations.

The configuration chart below lists fill volumes and service intervals for each engine and trim variant.

TypeSpecifications
  • Metrac H7 X, 39D/1 (2016-2022)
  • System, power steering
  • Use: Normal
  • Capacity 13 liter
  • Check 100 hours
  • Change 600 hours/ 24 months
  • Metrac H7 X, 39D/1 (2016-2022)
  • System, power steering
  • Use: First change only
  • Capacity 13 liter
  • Change 35 hours
  • Metrac H8 X, 34D/7 (2016-2022)
  • System, power steering
  • Use: Normal
  • Capacity 13 liter
  • Check 100 hours
  • Change 600 hours/ 24 months
  • Metrac H8 X, 34D/7 (2016-2022)
  • System, power steering
  • Use: First change only
  • Capacity 13 liter
  • Change 35 hours
  • Metrac H6 X (2011-2013)
  • System, power steering
  • Use: Normal
  • Capacity 13 liter
  • Check 100 hours
  • Change 600 hours/ 24 months
  • Metrac H6 X (2011-2013)
  • System, power steering
  • Use: First change only
  • Capacity 13 liter
  • Change 35 hours
  • Metrac H7 X (2011-2013)
  • System, power steering
  • Use: Normal
  • Capacity 13 liter
  • Check 100 hours
  • Change 600 hours/ 24 months
  • Metrac H7 X (2011-2013)
  • System, power steering
  • Use: First change only
  • Capacity 13 liter
  • Change 35 hours
  • Metrac 4004 (1992-2000)
  • System, power steering
  • Use: Normal
  • Capacity 13 liter
  • Check 200 hours
  • Change 600 hours/ 24 months
  • Metrac 4004 H (1992-2000)
  • System, power steering
  • Use: Normal
  • Capacity 13 liter
  • Check 200 hours
  • Change 600 hours/ 24 months
  • Metrac 2003 (1989-2000)
  • System, power steering
  • Use: Normal
  • Capacity 8 liter
  • Check 200 hours
  • Change 600 hours/ 24 months
  • Metrac 3003, S, K (1989-2000)
  • System, power steering
  • Use: Normal
  • Capacity 8 liter
  • Check 200 hours
  • Change 600 hours/ 24 months

Additional Notes

  • The Reform Metrac power steering specifications cover a combined hydraulic and power steering system, meaning the listed fluid capacity represents the shared reservoir that serves both functions simultaneously.
  • The Metrac 2003 and the Metrac 3003, 3003 S, and 3003 K all share an 8-liter hydraulic and power steering system capacity for their 1989-2000 production years, with identical check and change intervals of 200 hours and 600 hours or 24 months respectively.
  • The Metrac 4004 and 4004 H, produced from 1992-2000, carry a 13-liter system capacity, which is notably larger than the 8-liter figure of the earlier 2003 and 3003 variants, reflecting a greater total hydraulic volume in the larger platform.
  • All 1989-2000 variants share the same check interval of 200 hours, while the H-series models from 2011 onward specify a tighter 100-hour check interval, indicating more frequent fluid condition monitoring for the later machines.
  • The H-series models introduced from 2011 onward carry a first-change-only interval of 35 hours. A first-change interval at low hours is standard practice for new or rebuilt hydraulic systems, allowing metal particles and assembly residues generated during initial break-in to be flushed before the regular service schedule begins.
  • The Metrac H6 X and H7 X, both covering 2011-2013, each specify the 35-hour first-change interval alongside the standard 600-hour or 24-month change cycle, with the two intervals operating as distinct service events rather than alternatives.
  • The Metrac H7 X in its 39D/1 engine configuration, produced from 2016-2022, retains the same 13-liter capacity and identical normal and first-change intervals as the earlier 2011-2013 H7 X, indicating no change to hydraulic system volume between those generations.
  • The Metrac H8 X in its 34D/7 configuration, produced from 2016-2022, also specifies a 13-liter capacity with a 100-hour check, a 600-hour or 24-month change interval, and a 35-hour first-change requirement, matching the H7 X 39D/1 specifications exactly.
  • The 24-month time limit paired with the 600-hour change interval means a fluid change is due when either threshold is reached first, which is relevant for machines with low annual operating hours that might not accumulate 600 hours within two years.