Deutz-Fahr Agrotron TTV

Differential fluid capacity & service interval

Deutz-Fahr Agrotron TTV uses differential fluid with a capacity of 5,8 liters. Service intervals include checks at 250 hours and fluid changes at 1000 hours or 12 months and 1200 hours. The data covers 9 configurations.

The configuration chart below lists fill volumes and service intervals for each engine and trim variant.

TypeSpecifications
  • TTV 410, Stage 3A (2011-2015)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • TTV 420, Stage 3A (2011-2015)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • TTV 430, Stage 3A (2011-2015)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • TTV 610, Stage 3A (2009-2012)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • Check 250 hours
  • Change 1000 hours/ 12 months
  • TTV 620, Stage 3A (2009-2012)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • Check 250 hours
  • Change 1000 hours/ 12 months
  • TTV 630, Stage 3A (2009-2012)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • Check 250 hours
  • Change 1000 hours/ 12 months
  • 1130 TTV (2002-2008)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • Change 1200 hours
  • 1145 TTV (2002-2008)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • Change 1200 hours
  • 1160 TTV (2002-2008)
  • Front
  • Use: Normal
  • Capacity 5,8 liter
  • Change 1200 hours

Additional Notes

  • Across all listed Deutz-Fahr Agrotron TTV configurations from 2002-2015, the front differential fluid capacity is uniformly 5.8 liters, a figure consistent with a standard service fill rather than an overhaul or dry-fill quantity.
  • The 1130 TTV, 1145 TTV, and 1160 TTV (2002-2008) share an identical front differential change interval of 1200 hours under normal use conditions.
  • The TTV 410, TTV 420, and TTV 430 Stage 3A models (2011-2015) carry the same 5.8-liter front differential capacity as the earlier 2002-2008 generation, with no change interval listed in the specifications for those variants.
  • The TTV 610, TTV 620, and TTV 630 Stage 3A models (2009-2012) introduce a two-stage service schedule for the front differential: a fluid level check at 250 hours, followed by a full fluid change at 1000 hours or 12 months, whichever comes first under normal use conditions.
  • The time-based threshold of 12 months paired with the 1000-hour interval on the TTV 610-630 Stage 3A series means the calendar limit can trigger a fluid change before the hour count is reached, which is relevant for machines operating at lower annual usage.
  • The shift from a 1200-hour change interval on the 2002-2008 models to a 1000-hour interval on the 2009-2012 Stage 3A 600-series represents a shorter service cycle by 200 hours, despite the front differential capacity remaining unchanged at 5.8 liters.
  • Stage 3A refers to EU emissions compliance tier applied to the engine, and the 600-series Stage 3A designation on the 2009-2012 models places them in a higher power class within the Agrotron TTV range compared to the 400-series Stage 3A variants introduced in 2011.

Other Systems