Deutz-Fahr Agrotron 120-180.7

Coolant capacity & service interval

Deutz-Fahr Agrotron 120-180.7 uses coolant with a capacity range of 17,5 to 28 liters. Service intervals include a check every 10 hours and a change every 24 months. The data covers 6 configurations.

The configuration chart below lists fill volumes and service intervals for each engine and trim variant.

TypeSpecifications
Agrotron 120 (2005-2007)
  • Use: Normal
  • Capacity 17,5 liter
  • Check 10 hours
  • Change 24 months
Agrotron 130 (2005-2007)
  • Use: Normal
  • Capacity 17,5 liter
  • Check 10 hours
  • Change 24 months
Agrotron 150 (2005-2007)
  • Use: Normal
  • Capacity 17,5 liter
  • Check 10 hours
  • Change 24 months
Agrotron 150.7 (2005-2007)
  • Use: Normal
  • Capacity 28 liter
  • Check 10 hours
  • Change 24 months
Agrotron 165.7 (2005-2007)
  • Use: Normal
  • Capacity 28 liter
  • Check 10 hours
  • Change 24 months
Agrotron 180.7 (2005-2007)
  • Use: Normal
  • Capacity 28 liter
  • Check 10 hours
  • Change 24 months

Additional Notes

  • The Deutz-Fahr Agrotron 120-180.7 range splits into two distinct cooling system capacity groups across the 2005-2007 model years. The Agrotron 120, 130, and 150 share a 17.5-liter cooling system, while the Agrotron 150.7, 165.7, and 180.7 each require 28 liters.
  • The capacity jump from 17.5 liters to 28 liters between the non-.7 and .7 suffix variants reflects a larger engine displacement or a more complex cooling circuit in the higher-output models. A 60% increase in coolant volume is consistent with a physically larger engine block and expanded radiator capacity.
  • All six variants across the 2005-2007 range share an identical check interval of every 10 operating hours. At that frequency, coolant level verification is treated as a routine pre-operation or early-operation task rather than a periodic maintenance event.
  • The 24-month coolant change interval applies uniformly across all variants under normal use conditions. A time-based interval of this length is typical for modern ethylene glycol or organic acid technology coolants, which degrade through additive depletion over time regardless of operating hours accumulated.
  • The Agrotron 150 and Agrotron 150.7 carry the same nominal horsepower designation but differ in cooling system capacity by 10.5 liters. The .7 suffix denotes a different engine family, which accounts for the substantially larger cooling system requirement despite the shared model number prefix.