Case - IH Quantum V
Coolant capacity & service interval
Case IH Quantum V coolant capacity ranges from 10 to 16 liters. Service intervals include checking every 10 hours and changing every 1200 hours or 24 months. The data covers 8 configurations.
The configuration chart below lists fill volumes and service intervals for each engine and trim variant.
| Type | Specifications |
|---|---|
| Quantum 100V (2018- ) |
|
| Quantum 110V (2018- ) |
|
| Quantum 80V (2018- ) |
|
| Quantum 90V (2018- ) |
|
| Quantum 65V (2008-2014) |
|
| Quantum 75V (2008-2014) |
|
| Quantum 85V (2008-2014) |
|
| Quantum 95V (2008-2014) |
|
Additional Notes
- The Case - IH Quantum V cooling system capacity varies by model generation. The 2008-2014 variants (65V, 75V, 85V, and 95V) hold 10 liters, while the later 80V, 90V, 100V, and 110V models introduced from 2018 onward hold 14 liters, reflecting a 40% increase in cooling system volume.
- All models across both generations show a two-tier capacity figure. The base capacity applies to the engine cooling circuit alone, while the higher figure accounts for the addition of a cabin heating circuit. On 2008-2014 models, the cabin-inclusive capacity rises to 12 liters versus the base 10 liters. On 2018-onward models, the cabin-inclusive figure reaches 16 liters versus the base 14 liters.
- The 2-liter difference between base and cabin-inclusive capacities is consistent across all listed variants, regardless of generation. A technician filling a cabin-equipped unit without accounting for the additional circuit volume would underfill the system by exactly 2 liters.
- Coolant check intervals for the 2018-onward models are specified at every 10 operating hours under normal use conditions. No equivalent check interval appears in the specifications for the 2008-2014 models.
- The coolant change interval for the 80V, 90V, 100V, and 110V is set at 1200 hours or 24 months, whichever comes first under normal use conditions. The dual-trigger format means calendar time can mandate a change even when the hour threshold has not been reached, which is relevant for lower-utilization machines.
- No coolant change interval is listed in the specifications for the 2008-2014 Quantum V models (65V, 75V, 85V, and 95V). Only capacity figures are recorded for those variants.
- The four 2018-onward models (80V, 90V, 100V, and 110V) share identical cooling system specifications across capacity, check interval, and change interval, despite spanning a range of power outputs. The 2008-2014 models (65V, 75V, 85V, and 95V) similarly share identical capacity figures across all four variants.