New Holland Boomer
Coolant capacity & service interval
New Holland Boomer coolant capacity ranges from 3,8 to 7,5 liters. Service intervals include checking at 10 hours and changing at 1000 hours. The data covers 8 configurations.
The configuration chart below lists fill volumes and service intervals for each engine and trim variant.
| Type | Specifications |
|---|---|
| Boomer 20, PIN 2197012288-> (2013-2018) |
|
| Boomer 25, PIN 2199012668-> (2013-2018) |
|
| Boomer 30, PIN 2107015120-> (2013-2018) |
|
| Boomer 35, PIN 2109016019-> (2013-2018) |
|
| Boomer 40, PIN 2103014860-> (2013-2018) |
|
| Boomer 40 CAB (2013-2018) |
|
| Boomer 50, PIN 2105013792-> (2013-2018) |
|
| Boomer 50 CAB (2013-2018) |
|
Additional Notes
- The New Holland Boomer 20 and Boomer 25 share an identical cooling system capacity of 3.8 liters, while the Boomer 30 and Boomer 35 both require 4.5 liters, reflecting the larger engine displacement in the higher-numbered models.
- The Boomer 40 and Boomer 50 in standard (non-CAB) configurations carry a cooling system capacity of 6 liters, whereas the CAB variants of both models require 7.5 liters under normal use conditions, a difference of 1.5 liters attributable to the additional thermal load of the enclosed cab climate system.
- All eight configurations share a uniform coolant check interval of 10 hours under normal use conditions. On tractors that see frequent or demanding operation, a 10-hour check interval helps catch early signs of coolant loss or contamination before significant engine damage occurs.
- The coolant change interval is set at 1,000 hours across all Boomer models in the 2013-2018 range under normal use conditions. A 1,000-hour interval is a common benchmark for tractor cooling systems, balancing additive depletion rates with practical service scheduling in agricultural settings.
- Each row is tied to a specific PIN (Product Identification Number) starting point, such as PIN 2197012288 for the Boomer 20 and PIN 2199012668 for the Boomer 25. These PIN thresholds indicate that the listed cooling system specifications apply only to units produced from those serial numbers onward within the 2013-2018 model years.
- The Boomer 40 CAB and Boomer 50 CAB entries do not carry a PIN qualifier, unlike the standard open-station variants. The standard Boomer 40 is qualified from PIN 2103014860 onward, and the standard Boomer 50 from PIN 2105013792 onward.
- The capacity step from 4.5 liters on the Boomer 35 to 6 liters on the standard Boomer 40 represents the largest single capacity increase between adjacent models in the lineup, suggesting a meaningful change in engine size or cooling circuit design at that model boundary.